Juniper-networks SRX 210 Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
Table 5 on page 8 provides information on the physical specifications of the device.
Table 5: SRX210 Services Gateway Specifications
ValueSpecification
1.73 in. x 11.02 in. x 7.13 in.
44 mm x 280 mm x 181 mm
Dimensions (H x W x D)
3.46 lb (1.57 kg) for SRX210 Services Gateway
without PoE (no interface modules)
3.55 lb (1.61 kg) for SRX210 Services Gateway with
PoE (no interface modules)
Chassis weight
SRX210 Services Gateway Low Memory model: 27
watts
SRX210 Services Gateway High Memory model: 28
watts
SRX210 Services Gateway PoE model: 34 watts
(excluding PoE load)
Average power consumption
No performance degradation up to 10,000 ft (3048
m) for SRX210 Services Gateway Low Memory, High
Memory, and PoE models
Altitude
5% to 90%, noncondensingRelative humidity
Normal operation ensured in temperature range of
32°F (0°C) to 104°F (+40°C)
Nonoperating storage temperature in shipping
container: –40°F (–40°C) to 158°F (70°C)
Temperature
NOTE: These specifications are estimates and subject
to change.
SRX210 Services Gateway Low Memory: 120
BTU/hour
SRX210 Services Gateway High Memory: 126
BTU/hour
SRX210 Services Gateway with PoE: 164 BTU/hour
(Excluding PoE load)
Maximum thermal output
29.1 dB per EN ISO 7779Noise level
CAUTION: Before removing or installing components of afunctioningservices
gateway, attach an electrostatic discharge (ESD) strap to an ESD point and
place the other end of the strap around your bare wrist. Failure to use an ESD
strap could result in damage to the services gateway.
Copyright © 2013, Juniper Networks, Inc.8
SRX210 Services Gateway Hardware Guide
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 175 176

Comentarios a estos manuales