Juniper Networks FI-6000NS Manual de usuario Pagina 79

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 357
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 78
3.5 Using the System Settings Menus
Network Scanner fi-6000NS Operator's Guide 53
Administrator Operations
3
5. In Step 4, if [Middle] or [Top & Bottom] is selected, enter both "#1" (upper limit) and
"#2" (lower limit).
#1: Even numbers from 0 to 508mm can be entered. Odd numbers will be made even by
adding one.
#2: Even numbers from 0 to 510mm can be entered. Odd numbers will be made even by
adding one.
6. Press the [OK] button.
The document area to be monitored for multifeeds is set.
ATTENTION
Specify a larger value for "#1" than for "#2".
"#2" can have a maximum value of 510mm. If the paper size setting
is long page mode but the length of the document is longer than
510mm, multifeed cannot be detected by length.
When [Middle] is selected, if the document is shorter than "#1",
multifeed will not be detected. When [Top & Bottom] is selected, if the
document is shorter "#2", multifeed will not be detected for the
bottom part.
If the values specified for "#1" and "#2" exceed the actual paper size,
multifeeds will not be detected.