5.5 Replacing Parts
Network Scanner fi-6000NS Operator's Guide 223
Scanner Care
5
5. Remove the pick roller from the shaft.
Lift up the lock tab and slide the pick roller off the shaft.
6. Attach the new pick roller.
Insert the shaft into the new pick roller, aligning the protruding pin on the shaft with the
matching notch in the pick roller.
ATTENTION
Take care if lifting the pick roller lock tab with your fingernail as it
may get chipped or broken. If worried, try lifting the tab using a
paper clip as shown in the following diagram.
ATTENTION
Make sure that the pick roller shaft is fully inserted. If it is not
correctly attached, document jams and other feeding errors may
occur. You should hear a "click" when the pick roller shaft is inserted
correctly. Make sure you hear this noise when inserting the shaft
into the pick roller.
1
2
Pin on shaft
Pick roller notch
"Click"