Juniper-networks MX480 Manual de usuario Pagina 254

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 366
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 253
Figure 119: Installing an AC Power Supply in an MX480 Router
Related
Documentation
Preventing Electrostatic Discharge Damage to an MX480 Router on page 248
MX480 AC Power Supply Description on page 42
Replacing an MX480 DC Power Supply
1.
Removing an MX480 DC Power Supply on page 230
2.
Installing an MX480 DC Power Supply on page 232
Removing an MX480 DC Power Supply
Before you remove a power supply, be aware of the following:
NOTE: The minimum number of powersuppliesmustbe presentin therouter
at all times.
WARNING: Before performing DC power procedures, ensure that power is
removed from the DC circuit. To ensure that all power is off, locate the circuit
breaker on the panel board that services the DC circuit, switch the circuit
breaker to the off position, and tape the switch handle of the circuit breaker
in the off position.
CAUTION: To maintain proper cooling and prevent thermal shutdown of the
operating power supply unit, each power supply slot must contain either a
Copyright © 2013, Juniper Networks, Inc.230
MX480 3D Universal Edge Router Hardware Guide