CHAPTER 3
Installing ERX Modules
3-8
Figure 3-6 Installing an SRP I/O module in the ERX-1400 series
7 Tighten the module’s captive screws using a Phillips screwdriver.
Turn both screws several times before tightening them completely to
allow the module to sit correctly.
Installing an SRP Module
To install an SRP module:
1 Connect the antistatic wrist strap to the ESD grounding jack on your
ERX system.
Caution: When handling modules, use an antistatic wrist strap connected to the
ERX system’s ESD grounding jack. This action helps to protect the module from
damage by electrostatic discharge.
2 Choose the chassis slot where you want to insert the module.
For the ERX-1400 series, use slot 6 or 7; for the ERX-700 series, use
slot 0 or 1.
3 With a Phillips screwdriver, loosen the top and bottom screws that
secure the blank faceplate covering the empty chassis slot.
4 Remove the faceplate.